Some devices have temperature function, such as JT701D, but need to configure the corresponding sensor(JT126 sensor) to get the temperature, then you can configure it in the temperature and humidity sensor configuration.
Binding sensor:
Select the device that needs to configure the sensor, enter the sensor ID, support up to 4 sensors, and need to interact with the device during configuration, so it needs to be configured when the device is online.
After the configuration is successful, the sensor can start to detect the temperature and transmit the temperature data to the device. The temperature data can be viewed in the Report Center-Temperature and Humidity Report.
Unbind the sensor:
If the sensor needs to be unbound from the device, click the unbound icon at the back to unbound. You also need to operate the device while the device is online. After unbound successfully, the sensor will no longer upload temperature data to the device.
Synchronize:
In addition to the configuration of the sensor in the software, it is often configured through the device configuration tool, so the sensor data can be synchronized through the synchronization function to ensure the accuracy of the data.